B300 Bridge Instructions & Contents – Item #10040 & Item #10050

Welcome to the B300 Training Video and Guide CLICK HERE TO DOWNLOAD THE GUIDE

This page consists of instructions for those of you who purchased a B300 Bridge with product numbers 10040 or 10050, which includes the stainless-steel spring style injector.

We hope you find this library of information useful. If you have any questions about our products or technical questions about a repair don’t hesitate to give us a call at 800-548-8332.


Maintenance:

Inspecting and Maintaining the Cup

  • First, clean the cup surface according to the directions (See Cleaning).
  • Use a 600 grit or finer sandpaper to remove any glaze that’s built up on the edge of the rubber cup. Lay the sandpaper on a flat surface and set the cup face down on top of it. Rotate the cup left and right to gently sand the edge of the cup, keeping the cup and sandpaper flat at all times.
  • Inspect the cup for damage. Inspect the rubber carefully and replace it if there are any cuts, tears or other damage to the cup.
  • Check the air filter. Make sure the cup’s air filter is in place. If not, discontinue use until after replacing the filter.

Inspecting the Vacuum Pump Filter and Seal.

  • Remove the plastic plunger on the pump by pulling it straight out of the plastic cylinder and check to see if there are any cuts, tears, or other damage to the seal at the end of the plunger.
  • Every 200 repairs, inspect the seal in the pump to see if it needs lubricant. If so, apply a thin layer of a non-petroleum based lubricant.
  • Check to see that the plastic pump is clean and free from obstruction. If there are any cracks in the plastic or damage to the plunger seal, the pump must be replaced.
  • Check to see that there are no cracks in the plastic pump. Use a magnifying glass and pay particular attention to the area around the nipple that fits into the rubber cup.
Your Cart
0